MF研究者総覧

教員活動データベース

Force and electromyography responses during isometric force release of different rates and step-down magnitudes

発表形態:
原著論文
主要業績:
主要業績
単著・共著:
共著
発表年月:
2019年10月
DOI:
10.1016/j.humov.2019.102516
会議属性:
指定なし
査読:
有り
リンク情報:

日本語フィールド

著者:
Choi, Jeewon; Yeoh, Wen Liang; Loh, Ping Yeap; Muraki, Satoshi
題名:
Force and electromyography responses during isometric force release of different rates and step-down magnitudes
発表情報:
Human Movement Science 巻: 67 ページ: -
キーワード:
概要:
This study investigated motor responses of force release during isometric elbow flexion by comparing effects of different ramp durations and step-down magnitudes. Twelve right-handed participants (age: 23.1 ± 1.1) performed trajectory tracking tasks. Participants were instructed to release their force from the reference magnitude (REF; 40% of maximal voluntary contraction force) to a step-down magnitude of 67% REF or 33% REF and maintain the released magnitude. Force release was guided by ramp durations of either 1 s or 5 s. Electromyography of the biceps brachii and triceps brachii was performed during the experimental task, and the co-contraction ratio was evaluated. Force output was recorded to evaluate the parameters of motor performance, such as force variability and overshoot ratio. Although a longer ramp duration of 5 s decreased the force variability and overshoot ratio than did shorter ramp duration of 1 s, higher perceived exertion and co-contraction ratio were followed. Force variability was greater when force was released to the step-down magnitude of 33% REF than that when the magnitude was 67% REF, however, the overshoot ratio showed opposite results. This study provided evidence proving that motor control strategies adopted for force release were affected by both duration and step-down magnitude. In particular, it implies that different control strategies are required according to the level of step-down magnitude with a relatively short ramp duration.
抄録:

英語フィールド

Author:
Choi, Jeewon; Yeoh, Wen Liang; Loh, Ping Yeap; Muraki, Satoshi
Title:
Force and electromyography responses during isometric force release of different rates and step-down magnitudes
Announcement information:
Human Movement Science Vol: 67 Page: -
An abstract:
This study investigated motor responses of force release during isometric elbow flexion by comparing effects of different ramp durations and step-down magnitudes. Twelve right-handed participants (age: 23.1 ± 1.1) performed trajectory tracking tasks. Participants were instructed to release their force from the reference magnitude (REF; 40% of maximal voluntary contraction force) to a step-down magnitude of 67% REF or 33% REF and maintain the released magnitude. Force release was guided by ramp durations of either 1 s or 5 s. Electromyography of the biceps brachii and triceps brachii was performed during the experimental task, and the co-contraction ratio was evaluated. Force output was recorded to evaluate the parameters of motor performance, such as force variability and overshoot ratio. Although a longer ramp duration of 5 s decreased the force variability and overshoot ratio than did shorter ramp duration of 1 s, higher perceived exertion and co-contraction ratio were followed. Force variability was greater when force was released to the step-down magnitude of 33% REF than that when the magnitude was 67% REF, however, the overshoot ratio showed opposite results. This study provided evidence proving that motor control strategies adopted for force release were affected by both duration and step-down magnitude. In particular, it implies that different control strategies are required according to the level of step-down magnitude with a relatively short ramp duration.