MF研究者総覧

教員活動データベース

Effect of the surface form of the herringbone aluminum plate in a plate heat exchanger on the boiling heat transfer performance of ammonia

発表形態:
原著論文
主要業績:
主要業績
単著・共著:
共著
発表年月:
2024年11月
DOI:
10.1016/j.applthermaleng.2024.124057
会議属性:
指定なし
査読:
有り
リンク情報:
Applied Thermal Engineering

日本語フィールド

著者:
ARIMA, Hirofumi; NISHIGUCHI, Masanao; SUEHIRO, Syouichi
題名:
Effect of the surface form of the herringbone aluminum plate in a plate heat exchanger on the boiling heat transfer performance of ammonia
発表情報:
Applied Thermal Engineering 巻: 256 ページ: -
キーワード:
概要:
In this study, ammonia boiling heat transfer coefficient and the overall heat transfer were measured in a plate evaporator for an ocean thermal energy conversion (OTEC) system using aluminum plates. The OTEC system used ammonia as the working and a plate heat exchanger (PHE) that combined titanium plates. In this study, we used an anodized aluminum herringbone plate with two chevron angles of 45 and 60° installed in a PHE and measured the boiling heat transfer coefficients of ammonia and overall heat transfer coefficients for both plates to compare their heat transfer performances. The experimental conditions included a hot water flow rate of 1 – 12 L/min, a working fluid mass flux of 7 – 30 kg/m2s, a hot water inlet temperature of 30 – 40 °C, and a system pressure of 700 kPa. It was observed that anodized aluminum can be used as a heat-transfer plate for the PHE. In addition, the maximum overall heat transfer coefficient of chevron angle of 45° was 4 kW/m2K, and that of 60° was 3.5 kW/m2K, respectively. The maximum ammonia boiling heat transfer coefficient of 45° was 12.5 kW/m2K, and that of 60° was 13 kW/m2K, respectively. The heat transfer coefficient values are similar. Additionally, the correlation between the nondimensional heat transfer and the Lockhart-Martinelli parameter of aluminum plates was also clarified for comparison with the previous ammonia plate heat transfer in a flat plate. By comparing the correlation equations, the aluminum plate exhibited a value twice that of the flat plate.
抄録:

英語フィールド

Author:
ARIMA, Hirofumi; NISHIGUCHI, Masanao; SUEHIRO, Syouichi
Title:
Effect of the surface form of the herringbone aluminum plate in a plate heat exchanger on the boiling heat transfer performance of ammonia
Announcement information:
Applied Thermal Engineering Vol: 256 Page: -
An abstract:
In this study, ammonia boiling heat transfer coefficient and the overall heat transfer were measured in a plate evaporator for an ocean thermal energy conversion (OTEC) system using aluminum plates. The OTEC system used ammonia as the working and a plate heat exchanger (PHE) that combined titanium plates. In this study, we used an anodized aluminum herringbone plate with two chevron angles of 45 and 60° installed in a PHE and measured the boiling heat transfer coefficients of ammonia and overall heat transfer coefficients for both plates to compare their heat transfer performances. The experimental conditions included a hot water flow rate of 1 – 12 L/min, a working fluid mass flux of 7 – 30 kg/m2s, a hot water inlet temperature of 30 – 40 °C, and a system pressure of 700 kPa. It was observed that anodized aluminum can be used as a heat-transfer plate for the PHE. In addition, the maximum overall heat transfer coefficient of chevron angle of 45° was 4 kW/m2K, and that of 60° was 3.5 kW/m2K, respectively. The maximum ammonia boiling heat transfer coefficient of 45° was 12.5 kW/m2K, and that of 60° was 13 kW/m2K, respectively. The heat transfer coefficient values are similar. Additionally, the correlation between the nondimensional heat transfer and the Lockhart-Martinelli parameter of aluminum plates was also clarified for comparison with the previous ammonia plate heat transfer in a flat plate. By comparing the correlation equations, the aluminum plate exhibited a value twice that of the flat plate.