日本語フィールド
著者:*Jinichi Mori, Kumi Oshima, Tetsuya Tanimoto, Hikari Ishizuka, Shinya Kimura, Masatomo Miura, Naoto Takahashi題名:Pharmacokinetics of dasatinib in a hemodialysis patient with chronic myeloid leukemia and chronic kidney disease発表情報:Int J Hematol 巻: 112 号: 1 ページ: 115-117キーワード:概要:Until now, no studies have addressed the use of dasatinib in hemodialysis patients. Herein, we report the case of a 73-year-old hemodialysis patient with chronic myeloid leukemia (CML) who was treated with dasatinib. For 5 years prior, the patient had received nilotinib for the treatment of CML. Regular hemodialysis was initiated due to progression of hypertensive nephrosclerosis, whereupon nilotinib was discontinued and the patient began receiving 100 mg dose of dasatinib once daily. On dialysis days, dasatinib was administered immediately after completion of dialysis. Four months after starting dasatinib, we performed a pharmacokinetic study. The plasma concentrations of dasatinib before, immediately, and 2 h after the completion of hemodialysis were 7.4, 6.1, and 59.5 ng/mL, respectively. Ultrasound cardiography revealed a gradual decline in ejection fraction during dasatinib therapy. Because the patient's dasatinib trough concentration was higher (6.1 ng/mL) than the target level (1.5 ng/mL), we suspected the development of dasatinib-related heart dysfunction; thus, dasatinib was discontinued 6 months after its initiation. We concluded that hemodialysis patients are potentially vulnerable to the cardiotoxic effects of dasatinib; monitoring of cardiac function and plasma drug concentration may thus be useful in assessing their condition.抄録:英語フィールド
Author:*Jinichi Mori, Kumi Oshima, Tetsuya Tanimoto, Hikari Ishizuka, Shinya Kimura, Masatomo Miura, Naoto TakahashiTitle:Pharmacokinetics of dasatinib in a hemodialysis patient with chronic myeloid leukemia and chronic kidney diseaseAnnouncement information:Int J Hematol Vol: 112 Issue: 1 Page: 115-117An abstract:Until now, no studies have addressed the use of dasatinib in hemodialysis patients. Herein, we report the case of a 73-year-old hemodialysis patient with chronic myeloid leukemia (CML) who was treated with dasatinib. For 5 years prior, the patient had received nilotinib for the treatment of CML. Regular hemodialysis was initiated due to progression of hypertensive nephrosclerosis, whereupon nilotinib was discontinued and the patient began receiving 100 mg dose of dasatinib once daily. On dialysis days, dasatinib was administered immediately after completion of dialysis. Four months after starting dasatinib, we performed a pharmacokinetic study. The plasma concentrations of dasatinib before, immediately, and 2 h after the completion of hemodialysis were 7.4, 6.1, and 59.5 ng/mL, respectively. Ultrasound cardiography revealed a gradual decline in ejection fraction during dasatinib therapy. Because the patient's dasatinib trough concentration was higher (6.1 ng/mL) than the target level (1.5 ng/mL), we suspected the development of dasatinib-related heart dysfunction; thus, dasatinib was discontinued 6 months after its initiation. We concluded that hemodialysis patients are potentially vulnerable to the cardiotoxic effects of dasatinib; monitoring of cardiac function and plasma drug concentration may thus be useful in assessing their condition.